Retrofit Underfloor Heating for Old Buildings

Add warmth without stripping the floor: 0.5–3 mm film, 8–12 mm mats and no screed, so door heights and finished floors survive.

  • 0.5–3 mm build-up
  • no screed
  • 230 V
  • CE · RoHS
Heating film installed in a renovated apartment
SunAura | Qingdao

Retrofit underfloor heating is the version that fits an existing building: no screed, no pipework, no floor removal. A 0.5 mm heating film goes under floating laminate, a 8–12 mm mat goes into the adhesive bed under new tiles, and both keep the finished floor height within a few millimetres of the original.

The constraint in old houses is rarely the heat output — it is the door threshold, the stair nosing and the neighbour’s ceiling. This page collects the low-build options, the wiring rules that keep a 1930s or 1970s structure safe, and the 68 m² apartment retrofit we documented room by room.

01

Three ways to heat an old floor

02

Specifications for retrofit work

ParameterSpecification
Build-up0.5 mm film + 2–3 mm underlay; 8–12 mm mat plus 8–10 mm adhesive
Output80–160 W/m² film; 150–200 W/m² mat for stone or cold rooms
Existing floorsLaminate, engineered wood, LVT, new tile; not under solid hardwood or nailed boards
ElectricsDedicated circuit, 30 mA RCD, 16 A thermostat; spurs added at the consumer unit, not at a socket
CertificationCE & RoHS, double-insulated element, 100 % batch-tested in Qingdao
03

What decides the route

01

Measure the threshold first. If there is less than 6 mm to the door, film is the only option; 12 mm opens the mat route under new tiles.

02

Check the subfloor. Film needs a flat, sound surface; loose boards or a hollow screed must be made good before anything is laid.

03

Plan the circuit around the old board. A retrofit usually means a new 16 A circuit and an RCD at the consumer unit — budget for an electrician, not just the heater.

04

FAQ

Can film go under an existing floor?

Only if the floor can be lifted and re-laid — laminate and engineered wood usually can, solid hardwood and nailed boards cannot. The film always sits directly under the finished surface, never in the void beneath it.

Does retrofit heating need a new consumer unit?

Not always, but it needs a dedicated 16 A circuit with 30 mA protection. In older properties the board often has no spare way, so a small sub-board or a replacement unit is part of the cost.

Will 0.5 mm film heat a whole flat?

It heats the rooms it is under, typically 60–90 W/m² of installed area. Treat it as spot comfort — bathroom, kitchen, study — rather than whole-house heating unless the flat is well insulated.
05

Related scenarios

Next step

Send room dimensions, the floor build-up you want to keep, photos of the thresholds and the age of the wiring. We return a room-by-room retrofit plan with film or mat choice, circuit schedule and thermostat positions within one working day.

Last reviewed November 2026. Build-ups follow the current datasheet; confirm threshold heights before ordering.