Retrofit Underfloor Heating for Old Buildings
Add warmth without stripping the floor: 0.5–3 mm film, 8–12 mm mats and no screed, so door heights and finished floors survive.
- 0.5–3 mm build-up
- no screed
- 230 V
- CE · RoHS
Retrofit underfloor heating is the version that fits an existing building: no screed, no pipework, no floor removal. A 0.5 mm heating film goes under floating laminate, a 8–12 mm mat goes into the adhesive bed under new tiles, and both keep the finished floor height within a few millimetres of the original.
The constraint in old houses is rarely the heat output — it is the door threshold, the stair nosing and the neighbour’s ceiling. This page collects the low-build options, the wiring rules that keep a 1930s or 1970s structure safe, and the 68 m² apartment retrofit we documented room by room.
Three ways to heat an old floor

0.5 mm film under floating floor
The thinnest route: film laid on the existing subfloor, laminate or engineered wood straight over it. 80–160 W/m², no adhesive, reversible in an afternoon.
See the film range →
Aluminium film mat, 0.5 mm
For tiled finishes where height is critical: the aluminium carrier spreads heat sideways so the film does not need a thick bed. Cuts with scissors around pipes.
How the mat works →
Wall film where the floor cannot move
Heritage floors, screeds over joists or a listed stair: put the film on the wall instead. A 68 m² apartment did exactly this and kept every original threshold.
Read the case study →Specifications for retrofit work
| Parameter | Specification |
|---|---|
| Build-up | 0.5 mm film + 2–3 mm underlay; 8–12 mm mat plus 8–10 mm adhesive |
| Output | 80–160 W/m² film; 150–200 W/m² mat for stone or cold rooms |
| Existing floors | Laminate, engineered wood, LVT, new tile; not under solid hardwood or nailed boards |
| Electrics | Dedicated circuit, 30 mA RCD, 16 A thermostat; spurs added at the consumer unit, not at a socket |
| Certification | CE & RoHS, double-insulated element, 100 % batch-tested in Qingdao |
What decides the route
Measure the threshold first. If there is less than 6 mm to the door, film is the only option; 12 mm opens the mat route under new tiles.
Check the subfloor. Film needs a flat, sound surface; loose boards or a hollow screed must be made good before anything is laid.
Plan the circuit around the old board. A retrofit usually means a new 16 A circuit and an RCD at the consumer unit — budget for an electrician, not just the heater.
FAQ
Can film go under an existing floor?
Does retrofit heating need a new consumer unit?
Will 0.5 mm film heat a whole flat?
Related scenarios
Next step
Send room dimensions, the floor build-up you want to keep, photos of the thresholds and the age of the wiring. We return a room-by-room retrofit plan with film or mat choice, circuit schedule and thermostat positions within one working day.