Electric vs Hydronic vs Boiler Thermostats: Relay, Dry Contact, RS485 and RF Selection

WiFi thermostat with colour display and control interface

Most buyers shop a thermostat by its screen, its app and its colour, and then find the wrong output terminals on the back. The detail that actually decides whether a thermostat fits a heating system is the switching type it offers. A relay that carries the full electric load, a volt-free contact that only signals a boiler, an RS485 bus for building control, and an RF link for no-wire retrofit are not interchangeable. This guide explains each output, matches it to the load it serves, and uses the models and ratings from the SunAura thermostats product page so the correct version is specified the first time.

Start from the load, not the display

The switching question is really a question about what the thermostat is asked to switch. An electric film, mat or cable is a resistive load that draws real running current, so the thermostat has to carry and break that current through an internal relay rated for the amps. A wall-hung boiler, a hydronic zone valve or an actuator does not take its power through the room thermostat; it takes a signal, so the thermostat closes a dry contact that tells the appliance to start. A fan coil is switched and its speed selected, often over a control bus. A retrofit where a wall cannot be chased uses a wireless link instead of a fixed wire.

Get that distinction clear and the model choice follows. The same product family often ships in different output versions, so the part number is not complete until the output is chosen. The page lists a wide range, from the K1M and K2M to the K9, K5, KC02, K6H, SDM5 and SDM6, plus the RF WITH3 and a wired K1. The versions differ in load rating, 3 A dry contact, 16 A and 25 A, and in the buses and wireless options they carry.

WiFi thermostat with colour display showing the control interface
The screen is the visible part; the output terminals on the back are what match it to the heating system.

Direct relay: for electric resistive heating

A direct-switching, or relay, thermostat puts the heating load through its own contacts. When the room calls for heat, the relay closes and the full current of the film, mat or cable passes through it. The product page rates these versions at 16 A, with 20 A and 25 A options for larger zones. A 16 A relay handles a typical electric room inside its rating; a 20 A version, such as the KC02 option, switches a bigger zone without an external contactor; a 25 A backplate extends that further. The models accept a wide supply, around 90 to 240 VAC at 50/60 Hz, and hold an accuracy of about ±1 °C.

The relay rating is a hard ceiling, not a target to brush against. A zone whose running current is at or above the relay’s limit will pit the contacts over many cycles and can weld or burn them, which is why the load is calculated first and the relay chosen above it. Where a zone is too large for any direct version, the correct design uses a contactor: the thermostat switches the small contactor coil and the contactor carries the heater, as the thermostat load capacity guide explains. A relay thermostat should never be forced to handle a load it was not rated for by simply winding the temperature up.

Contact life and why the rating has margin built in

A relay is a mechanical switch with a finite number of operations, and its published life is given in two separate figures: mechanical life, the cycles it can make without load, and electrical life, the cycles under rated current. Breaking a live resistive load draws a small arc across the opening contacts, and over many cycles that arc wears the contact faces. Keeping the load below the rating, rather than running the contacts at their limit, is what lets the electrical life reach the long service window expected of a heating control. This is the engineering reason a margin is left between the running current and the relay ceiling, and why a zone that sits at the limit is a control that will fail early even though it never trips a breaker.

Resistive loads are kind to contacts compared with motors, which draw a starting surge, because a film or cable is a steady current with no inrush beyond a brief cold start. That is the same reason the direct versions are rated for the resistive heating duty rather than general motor use. A contactor follows the same logic at a larger scale: its coil is a small load the thermostat switches easily, and its heavy contacts are built to carry the heater. Choosing the relay and the contactor from their resistive ratings, rather than borrowing a motor-rated part, keeps the contact life calculation honest.

Volt-free dry contact: for boilers and hydronic zones

A dry contact, also called volt-free, is a set of contacts that carry no voltage of their own. Closing them completes a circuit inside the boiler or actuator, which supplies its own power and starts the burner, pump or zone valve. The product page rates these outputs at 3 A. The contact is a signal, not a power feed, so it is the correct output for a wall-hung boiler, a hydronic system or a motorised valve. The K2M is a useful dual version because it combines a 16 A electric relay with a 3 A dry contact in one unit, so a mixed home with an electric loop and a boiler can be controlled from a single thermostat.

Wiring a dry contact is different from wiring a relay. The two terminals are a clean switch loop to the appliance, and the thermostat does not pass the boiler’s operating current. Confusing the two is a common fault: a 3 A dry contact cannot carry an electric floor load and will fail if a heater is put through it, while a relay’s powered terminals are not the clean signal a boiler expects. The appliance’s own instructions define how its volt-free input is taken, and the thermostat is matched to that input rather than the other way round.

Smart thermostat with touch screen showing temperature and control options
Many smart models offer both a 16 A relay and a 3 A dry contact, selected by the version ordered.

RS485 and fan coil control

For fan coil units and integrated building work, the control is often a dry contact for switching plus an RS485 bus for speed and central control. The K9 on the product page carries an RS485 bus alongside its smart functions, which suits hotel and apartment projects where many rooms are managed together. The bus lets a building system read and set the room rather than an occupant operating each unit alone, and the dry contact handles the on-off call. Speed selection over the bus replaces separate manual switches.

The product page does not list a separate, dedicated fan-only model, and that should be reported honestly rather than invented. Fan coil control is delivered through the dry contact and RS485 capability of the project thermostats, not through a standalone fan part number. A buyer specifying fan coils should work from the RS485 and contact ratings and confirm the integration with the building system, rather than expecting a fictional dedicated model. Keeping the claim to what the page shows is what makes the specification defensible.

RF wireless: for no-wire retrofit

An RF, or radio frequency, system removes the need to run a wire between the room and the appliance. The product page lists the WITH3, a 433 MHz wireless boiler thermostat with a battery-powered transmitter and a receiver that switches the boiler through a 3 A contact. The transmitter sits in the room and the receiver at the boiler, talking over the air, so a wall-hung boiler retrofit needs no wall chasing. It keeps a seven-day schedule and app control while the receiver is powered at the appliance.

The choice between wired and wireless is a trade of reliability against installation. A fixed wire is immune to radio interference and never needs transmitter batteries, while the RF link fits an existing room where lifting floors or chasing walls is not practical. The electric versus hydronic heating guide works through the decision. The RF output here is a boiler signal at the receiver, not a way to carry a large electric floor load wirelessly, so it stays in the boiler and hydronic role rather than replacing a high-current relay.

Dual version thermostat showing relay and dry contact output options
A dual-output model: the relay feeds an electric loop while the dry contact signals a boiler.

Side-by-side: the four output types

Output Ratings Switches Best for Limits
Direct relay 16 A, 20 A, 25 A Full electric load Film, mat, cable resistive zones Hard current ceiling; larger zones need a contactor
Volt-free dry contact 3 A Signal to appliance Boilers, hydronic valves, actuators Cannot carry a heater load
RS485 plus contact Bus, project rated Switching and speed Fan coils, hotels, building control Needs a compatible building system
RF wireless 433 MHz, receiver 3 A Wireless boiler signal No-wire boiler retrofit Batteries, radio range, not high-current

Scene-by-scene: which output to specify

Electric floor in a normal room. A 16 A relay model such as the K1M carries the film or mat directly. Size the zone so its running current sits below the relay rating with margin.

Larger electric zone. Move to a 20 A or 25 A version, or use a contactor with a standard thermostat. Do not put an oversized load through a 16 A contact.

Wall-hung boiler. Take a 3 A dry contact model, or the WITH3 RF where no wire can be run. The boiler is signalled, not powered through the thermostat.

Mixed electric and hydronic home. The K2M dual version covers both a 16 A electric loop and a 3 A boiler call in one wall box.

Hotel and apartment fan coil projects. The K9 with RS485 gives central control and speed selection, with the dry contact handling the switch. Confirm the building integration before ordering.

RF wireless boiler thermostat receiver and transmitter for no-wire retrofit
The RF receiver at the boiler removes the wall wire in a retrofit.

Wiring and commissioning

Whichever output is used, the commissioning confirms the terminals match the load and the controls read correctly. Verify the supply, 90 to 240 VAC, the floor or air sensor, and the NTC probe where a floor limit is set, then confirm the relay or contact opens and closes on a call and the appliance responds to a dry contact or an RF pair. The heating element quality control guide and the underfloor heating lifespan guide cover the details. Record the load current against the relay rating and test the RCD, so a later contact failure is diagnosed against a known baseline rather than by guessing.

Zoning and circuit count across a whole building

The switching decision scales up when a whole building is planned. Each electric zone is a relay circuit limited by its contact rating, so a large floor is divided into zones that each fit within 16, 20 or 25 A, with each zone’s cold lead brought to its own control or to a panel with contactors. Hydronic zones are dry-contact calls, one per valve or actuator, and fan coil rooms are RS485 nodes on the same building system. The number of zones is therefore set by the electrical limits as much as by comfort, and the output types are mixed within one building rather than forcing a single relay across every load.

Balance the zones so no single relay or contactor carries a disproportionate load. A zone that is too large either trips its protection or pits its contacts, while over-splitting a small floor adds controls and cost without comfort. The practical method is to calculate the watts per room, match each to the smallest relay that covers it with margin, and reserve the dry contact and RS485 outputs for the appliances and building nodes that need them. On a project with many identical rooms, the RS485 bus turns the separate thermostats into a manageable system rather than a set of isolated units that have to be visited one by one.

Fault finding and standalone operation

When a control misbehaves, the output type points to the fault. A relay that closes but leaves the floor cold suggests a heater or supply problem rather than a control failure, while a relay that does not close on a call points to the thermostat or its sensor. A dry contact that does not start the boiler is checked with a continuity meter across the two terminals, since the signal is a clean switch loop. An RF link that drops is checked for range, receiver power and transmitter batteries, and an RS485 room that loses central control still works locally if the unit keeps its standalone functions.

That local operation is worth confirming. The product page notes the smart models run fully as standalone thermostats through their local buttons when the internet is down, so a network failure does not stop the heating. The app and voice control are an added layer rather than the only path. A sensor fault is the other common call: a floor probe reading high makes the control switch off early and a healthy system appear weak, which is checked against the real slab temperature before the heater is blamed. Keeping the commissioning baseline and the sensor readings on file lets these faults be separated quickly instead of replacing a working control.

Pre-inquiry parameter checklist

  1. Heating type: electric resistive, boiler, hydronic or fan coil.
  2. Load current in amps, to choose 16, 20 or 25 A relay.
  3. Whether the appliance needs a volt-free signal and its contact rating.
  4. Whether RS485 building integration and fan speed control are required.
  5. Whether a wire can be run, or an RF link is needed for retrofit.
  6. Supply voltage and the sensor type, floor NTC or air.
  7. For mixed systems, whether a dual-output model fits the wall box.
  8. App, schedule and voice needs, and whether standalone operation is required.

Questions buyers ask before they pick a version

Can one thermostat run both an electric floor and a boiler? A dual-output model such as the K2M can, with a 16 A relay for the electric loop and a 3 A dry contact for the boiler. A single-output relay cannot, so the dual version is specified rather than wiring two loads to one contact.

Is a dry contact the same as a switched live? No. A dry contact is a clean, volt-free loop the appliance powers itself. A switched live carries the thermostat’s supply and is not the signal a boiler’s volt-free input expects. The two are wired differently and should not be interchanged.

Does the RF system work if the internet drops? The 433 MHz link between transmitter and receiver is local radio, not dependent on the internet, so the boiler still switches on the schedule. App access is the part that needs the network, while the room-to-boiler signal keeps working.

How do I know if I need RS485? It is used when a building system has to read and control many rooms, typically hotels and apartments. A single home with local control does not need the bus and takes a standard relay or dry-contact model.

What if the load is just above 16 A? Move to the 20 A version rather than running the 16 A contact at its limit, or use a contactor. Pushing a relay to its ceiling shortens the contact life even when it does not trip.

Common mistakes

Putting a heater through a 3 A dry contact. The contacts are a signal and will fail under load. Electric floors take a rated relay.

Brushing the relay ceiling. A zone at the contact limit pits the relay. Leave margin or use a contactor.

Expecting a dedicated fan model. Fan coil control is delivered through RS485 and contacts, not a fictional standalone part.

Using RF to carry a high current. The wireless receiver signals a boiler at 3 A; it does not replace a high-current relay.

Ordering by screen alone. The output version is the part of the model number that makes the thermostat compatible.

Data and evidence

The output types follow standard electrical and controls practice. Switching relays, volt-free contacts and serial buses are defined in electrical engineering references, while national electrical codes and the IEC 60898 range govern the circuits and over-current protection these controls sit within. Building and HVAC research bodies, along with energy agencies, publish guidance on zoning, setback and the correct matching of controls to heat sources that supports selecting the output from the load rather than the interface. Established HVAC manufacturers document relay ratings, dry-contact inputs, RS485 protocols and RF pairing in their technical literature, which is the correct source for the integration details. The SunAura evidence is limited to what can be shown: manufacturing since 2008, ISO 9001/14001/45001 management, CE/RoHS/SGS and LVD/EMC documentation, a Qingdao Huangdao plant with six automated lines and an in-house laboratory, and exports to more than 50 countries. No certificate numbers, current figures or client names are invented, and no medical or hazardous-area claim is made.

Conclusion: what to choose

Choose the output to match the load, then pick the screen and app. A resistive electric floor takes a direct relay at 16, 20 or 25 A, with a contactor for any zone above the contact rating. A boiler or hydronic appliance takes a 3 A volt-free dry contact that signals rather than powers it, with the dual K2M covering a mixed home and the RF WITH3 handling a no-wire retrofit. A fan coil or building project takes the RS485 and contact control, specified honestly without inventing a dedicated fan model. Confirm the terminals, the load current and the sensor at commissioning and keep the records for every zone. The full range of models and their output versions are collected on the thermostat applications hub, where each heating system can be matched to the correct switching type and the right terminal rating before the order is placed.