Thermostats split by what they switch. Electric heating models carry a 16 A relay with 20 A and 25 A versions that directly cut film, mat and cable. Hydronic and boiler models use a volt-free dry contact rated 3 A, including the dual K2M (16 A electric plus 3 A boiler) and the WITH3 RF wireless unit on 433 MHz for wall-hung boilers. Fan coils are switched or speed-controlled through the dry contact or an RS485 relay rather than a separate model. All units run AC 90–240 V at 50/60 Hz and offer Tuya WiFi, a weekly six-period schedule, an NTC floor sensor (β=3950, 10 kΩ), child lock, antifreeze, power-off memory and voice control, with a 2-year warranty.

01

Thermostat buying and technical guides

02

Which switching type the system needs

01Direct electric heating

Film, mat and cable under 16 A use a direct relay; larger loads use 20 A or 25 A versions or an external contactor controlled by the thermostat.

02Boilers and hydronic systems

A volt-free 3 A dry contact fires the boiler, with the WITH3 RF giving a wireless option for wall-hung units and the K2M combining electric and boiler switching.

03Fan coils

A fan coil is switched or speed-controlled through the dry contact or the RS485 relay. There is no separate fan-coil model, so the control is specified from the unit interface.

03

Specification at a glance

ParameterStandard rangeWhat it means on site
Electric load16 A / 20 A / 25 ADirect relay switching
Boiler contact3 A volt-free dry contactHydronic and boiler
Fan coilDry contact / RS485Switch and speed control
VoltageAC 90–240 V, 50/60 HzSome 95–240 builds
Floor sensorNTC β=3950, 10 kΩRemote probe
WirelessWITH3 RF 433 MHzWall-hung boiler
Smart featuresTuya WiFi, voice, 6-periodAlexa/Google/Yandex
Warranty2 yearsCE, RoHS, SGS
04

How to specify it in five steps

01

Identify the load type. Direct electric, boiler dry contact or fan coil and pick the matching switching output.

02

Size the current. Stay under 16/20/25 A or add a contactor; never exceed the relay rating.

03

Choose sensor strategy. Floor NTC, air sensor or combined, and position the probe before the floor closes.

04

Wired or wireless. Wired for new build, RF for retrofit where a cable run is impractical.

05

Program and commission. Set the weekly schedule, antifreeze and app connection, then verify the load actually switches.

05

Where it is the wrong choice

Do not fit a direct 16 A thermostat to a load above its rating, and do not assume a dedicated fan-coil model exists — fan coils use the dry contact or RS485 path. A dry contact also cannot carry mains power directly; it only signals the boiler or relay.

06

Questions we get asked

What thermostat for heating film?

A 16 A direct model for a single room, or a 20/25 A version plus a contactor where several strips exceed the relay rating.

How does it control a boiler?

Through a volt-free 3 A dry contact; the thermostat supplies the signal, not the power, and the WITH3 RF does this wirelessly.

Can it run a fan coil?

Yes, via the dry contact or RS485 relay for switching and speed control; there is no separate fan-coil-specific model.

What sensor does it use?

An NTC floor probe at β=3950 and 10 kΩ, alongside an air sensor, with the strategy chosen by the floor type.

Which voice platforms are supported?

Tuya integration provides Alexa, Google and Yandex voice control alongside the app and weekly schedule.

Next step

Send the heating load, voltage and whether the system is electric, boiler or fan coil. We return the model, switching rating and sensor plan. Pairing and wiring details are on the product page and in the commissioning guide.

Last reviewed November 2026. Specifications reflect the current factory datasheet; confirm values before ordering.