Overview
The Y308/16 Knob Thermostat is the simplest controller in our range: a rotary knob that turns comfort up or down, and a clear panel that shows the target temperature. Built for electric heating and carbon film systems, it needs no menus, no app and no training — turn the dial and the room responds. It is the right choice for guest rooms, offices and buildings where occupants expect an intuitive dial, and it sits in our thermostats & controls family.
Use it with electric heating mats and carbon/graphene heating film. If you want scheduling, choose the E51.716 button thermostat; for app control, see the knob WiFi thermostat line.




Key Features
- Knob operation — one rotary dial: turn left to cool, right to warm; no menus to learn.
- Electric & carbon film heating — built for electric underfloor and carbon film systems.
- Robust public-building fit — used in hotels, hospitals, schools and office buildings.
- Familiar interface — occupants understand it instantly, reducing complaints and call-outs.
- 3 m NTC floor sensor — floor-temperature protection for sensitive finishes.
- Flame-retardant PC + ABS body — durable fascia for corridors and guest rooms.
- No network needed — works offline from day one, no pairing steps.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | Y308/16 |
| Type | Knob-type electric heating room thermostat |
| Heating systems | Electric underfloor heating; carbon film heating systems |
| Typical load | 16 A electric heating (confirm per project) |
| Control | Rotary knob, on-panel display |
| Sensor | Room sensor + 3 m external NTC floor sensor |
| Body material | Anti-flammable PC + ABS |
| Typical projects | Hotels, hospitals, schools, office buildings |
| Warranty | 2 years; online technical support, free spare parts, return & replacement |
| Certification | CE, RoHS |
Wiring & Installation
Mount on a standard recessed wall back box. Mains L/N terminals feed the unit; the load output switches the electric heating or carbon film circuit. Run the 3 m NTC floor sensor under the floor finish between two element runs. For loads above the rated current, switch a contactor from the output. After wiring, set the desired comfort level with the knob and confirm the floor-sensor limit. The circuit must be RCD-protected and finished by a qualified electrician.
Compatible Heating Systems
- Electric heating mats — tile and stone floor builds.
- Carbon / graphene heating film — renovations and wood-finish rooms.
- Heating cables — looped bathroom circuits.
- Hotel floor heating mat — hospitality room packages.
- Underfloor heating systems — full project design.
How It Works
Turning the knob sets the target room temperature. The thermostat compares the measured room (and floor-sensor) temperature against the dial position and switches the heating on until the room reaches the setpoint, then off. As the room drifts below, the cycle repeats — holding a steady band of comfort with no programming required. The floor sensor enforces a safe maximum floor temperature so laminate, wood and carpet are never overheated.
Safety & Certifications
Flame-retardant PC+ABS enclosure, 100 % factory testing, CE and RoHS certification under ISO 9001 production management. Floor-sensor protection guards sensitive finishes; the simple dial cannot be accidentally programmed into unsafe modes; freeze-protection bands hold empty rooms above freezing. RCD-protected supply completes safe installation.
Factory & Quality
SunAura Thermal has manufactured heating controls and elements in Qingdao since 2008, exporting to more than 50 countries. The Y308/16 is SMT-assembled and tested on our own lines, backed by a 2-year warranty with online technical support, free spare parts and return/replacement service. The whole control family sits in the thermostats & controls category.
Packaging & Shipping
Units box with the 3 m sensor, fixing kit and multilingual quick-start guide. Cartons are pallet-optimised for sea freight, with express courier for urgent replacements. CE/RoHS certificates and test records accompany the shipment; multilingual manuals and private-label fascia are available for distributor programmes.
OEM / ODM
Private label covers knob and fascia colours, silkscreen branding, custom packaging and multilingual manuals. ODM variants — dial scale designs, setpoint limits for hospitality, bundled mat-plus-knob-kits — are handled in-house. Samples are available before a bulk order, with flexible MOQ for new distributors.
Wholesale Pricing & How to Buy
Pricing is factory-direct and tiered by quantity; sample units are offered before bulk orders. Tell us the heating system, voltage and room count, and we will confirm the configuration and return a same-day quotation. Contact our sales team for factory price, wholesale terms and free-sample arrangements.
FAQ
Is the Y308 programmable?
No — it is a simple setpoint dial thermostat for users who want instant, no-menu control. Choose our programmable button or touch models when scheduled setback is needed.
Which systems does the knob thermostat control?
It is built for electric heating systems and carbon film heating systems, widely used in hotels, hospitals, schools and office buildings.
Does it protect wood or laminate floors?
Yes — with the supplied 3 m floor sensor, the thermostat caps floor temperature at the safe finish maximum, the same protection principle used across our controller range.
Do you offer a WiFi version of this knob control?
Yes — our knob WiFi thermostat line adds app control to the familiar dial. Ask us for the knob+app SKU when remote scheduling is required.
What is the warranty?
2 years, including online technical support, free spare parts and return/replacement service.
Related Products
More room controllers in the same range:
- Knob WiFi thermostat — same dial feel, app control added
- E51.716 button thermostat — programmable button alternative
- K1 thermostat — established SunAura room control
Back to the thermostats & controls collection, or request a wholesale quote for the Y308 knob thermostat.