Most installers waste film before they switch a single tool on. They order the roll that looks like the right total wattage, carry it into the room, and then start cutting against whatever wall they happen to face. The off-cuts pile up, a strip lands half under a kitchen unit, and two cold leads finish on the wrong side of the room. None of that is a product fault. It is a layout that was never drawn. The graphene heating film only performs and only pays back when the strips are planned against the floor plan first.
This guide is about the physical layout, not the wattage arithmetic. It covers how to read a room, pick the roll width, cut each strip to length, leave the correct gaps, route the cold leads back to the wall, and keep the waste percentage low. The numbers come from SunAura factory cut records and the way dry-floor builds are marked on site. A separate guide handles the heat-loss calculation; here the question is where every strip sits and why.

Why the strip layout comes before the wattage
The wattage tells you how much energy the room needs. The strip layout tells you where that energy physically fits. Both have to be right, and the layout is the one you cannot fix later. Once the floating floor clicks down, a short strip or a blocked cold lead means lifting boards.
Three constraints lock the layout in place, and they all come from the building rather than the heater.
The room footprint. Walls are never perfectly square, and the dimensions on the architect drawing rarely match the floor. The usable heated area is set by the real measurements, taken in the room, not off a plan.
The fixed objects. Anything that sits full-base on the floor cancels a strip. Kitchen cabinets, a built-in wardrobe, a bath, a fixed island, and floor-mounted toilets do not get heated and should not have film trapped under them. These objects carve the heated area into shapes before a single strip is cut.
The electrical entry point. The thermostat and the cold leads have to reach a wall. A strip that finishes in the middle of a room with no route back is a strip you have to re-run. The cold-lead side of the layout has to be decided early.
Get these three constraints on paper and the rest is a cutting problem. Ignore them and the job becomes a series of compromises that show up as cold spots, wasted film, and extra junction boxes.
The three numbers that define every strip
Every single strip in a dry-floor build is described by three numbers. If you can state these for each strip, you can quote the job and cut the roll without standing in the room.
Width. The film width across the roll, measured from one long edge to the other. SunAura floor film runs in twelve standard widths from 10 cm to 100 cm. The width decides how many strips cover a given span and how much edge waste the room produces.
Cut length. How long each strip runs from the cold-lead end to the far edge. Film is cut across its width at printed cut marks, so the length is stepped in fixed increments rather than cut to any millimetre. The cut-mark spacing is printed on the roll and is commonly around 20 to 25 cm between marks depending on the product line.
Spacing. The gap left between adjacent strips and the gap from the outer strip to the wall. Strips do not butt tight together. A small gap keeps the floating floor flat, lets the underlay breathe, and gives the cold leads a channel to run in.
Width and cut length are properties of the film itself. Spacing is a decision you make on the layout. Confusing the three is where most bad cut sheets start.
Reading the room: what the floor plan tells you
Before any strip is drawn, take the room in a fixed order. Skip this and the layout reflects the first wall you looked at rather than the room as a whole.
Measure the real walls. Pull a tape along each wall at floor level, and record both the overall dimensions and any alcoves or bay windows. Take a diagonal measurement as well; if the two diagonals differ, the room is out of square and the strips have to be set against the longest straight wall, not assumed parallel.
Mark every fixed object. Draw the footprint of cabinets, sanitaryware, door swings, and any pipe or duct boxes that rise from the floor. Shade the areas that cannot be heated. What is left is the actual heated footprint, and it is almost always smaller than the room area on the listing.
Locate the electrical supply. Note which wall the thermostat will sit on and where the circuit enters. Cold leads are easiest when they all run toward the same wall. Decide this now so the strips can be oriented with their cold-lead ends pointing the right way.
Check the floor build height. Measure the available height from the subfloor to the underside of the door and any threshold. The film, underlay, and new floor all add thickness, and a retrofit over an existing floor is the tightest case. This does not change the strip count, but it decides whether a slim aluminium mat replaces part of the film build.
A room measured this way gives up its layout quickly. The heated footprint, the blocked zones, and the cold-lead direction are all known before a roll is opened.

How to choose film width to cut waste
The single biggest lever on waste is the roll width, and it is chosen before the order is placed. A width that divides the room span evenly leaves almost no off-cuts. A width that does not divide leaves a narrow remainder that often cannot be used elsewhere.
Work the width against the room’s short dimension, because that is the span the strips cross. Divide the heated span by candidate widths and look at the remainder.
Large open rooms. A wide film, 80 to 100 cm, covers the span with fewer strips and fewer cold-lead connections. Fewer joints mean fewer points to seal and less labour. The trade-off is that a wide roll is stiffer to handle and a single off-cut is a large piece of waste.
Small rooms and corridors. A narrow film, 25 to 50 cm, follows the room better. A hallway that is 90 cm wide can be covered with two 40 cm strips and a controlled gap, where a 100 cm roll would force a long cut and a wide off-cut down the full length.
Broken floor plans. Alcoves, chimney breasts, and L-shaped rooms suit a mix of widths. Use a wide film across the main body and a narrow film in the returns, rather than cutting a wide film into awkward shapes.
The target is a waste share under about 10 percent of the heated area on a normal rectangular room, and a little higher on a broken plan. If the first width you try leaves a 15 cm remainder strip running the full room length, change the width rather than accepting the waste. The twelve-width range exists precisely so the roll can be matched to the span.
Cut length and the cut-mark system
Heating film is not trimmed to any length with a freehand cut. The heating element is a printed pattern, and cutting between the wrong marks would sever a live path. The roll is printed with cut lines that cross the full width, and the film is only cut across these lines.
How the marks work. Each cut line sits in a blank section of the PET between the printed heating zones, with the copper busbars interrupted on either side. Cutting on the line leaves a sealed, safe edge. The marks are usually spaced at a regular interval, so the available strip lengths form a sequence rather than a continuum.
Choosing the length. Measure the run the strip has to cover, including the edge gap at the far wall, then pick the nearest cut mark that is not shorter than the run. A strip that is slightly too long can be managed against the wall gap. A strip that is too short leaves a cold band at the far edge and cannot be extended.
Never cut the long edges. The two long edges carry the running busbars. Trimming the width by cutting lengthwise would open the busbar and ruin the strip. Width is fixed at manufacture; only the cut length is adjusted on site.
Keep the cut edge sealed. After a cross-cut, the new edge is the end that needs the cold-lead terminal or an end cap, depending on the product. Treat the cut as a working edge that has to be finished, not as a throwaway edge.
Because the cut lengths are stepped, the layout should list the cut length for every strip against the mark sequence. Two strips that look the same on the drawing may need different marks once the real wall dimensions and the edge gaps are added.
The strip layout comparison table
This table ties the room shape to the width and cutting approach. Keep it open when the roll is being specified. The waste figures are the kind of share that comes from a planned cut sheet, not a freehand job.
| Room shape | Film width | Strip orientation | Likely waste | Strength | Watch point |
|---|---|---|---|---|---|
| Large open rectangle | 80–100 cm | Parallel across the short span | 5–8% | Few strips, few cold leads | Wide off-cut if the span is misjudged |
| Small bedroom | 50–60 cm | Parallel, cold leads to one wall | 7–10% | Easy to handle, even coverage | More strips and terminals to seal |
| Hallway / corridor | 25–40 cm | Lengthwise, narrow strips | 8–12% | Follows a tight width | Long cold-lead run back to the entry |
| L-shaped / broken plan | Wide + narrow mix | Separate runs per zone | 10–15% | Each return covered cleanly | Needs a clear zone break and junction plan |
| Room with fixed units | Matched to the gaps | Strips stop at unit faces | 10%+ | No film trapped under cabinetry | Easy to run a strip too far under a unit |
| Retrofit over existing floor | 50 cm or 0.5 mm mat | Floating, minimal build | 8–12% | Low height, no screed | Door and threshold height can force a mat |
Read the waste column as a planning result, not a fixed property of the film. The same roll in the same room can land at 6 percent or 18 percent depending on whether the width was matched to the span before ordering. A wide film is not automatically better; it is only better when the room span justifies it.
Working around fixed furniture and floor openings
The heated area is the floor that stays open and visible. Planning around what is fixed is what separates a clean layout from a room with dead film under the cabinets.
Full-base furniture. A wardrobe or kitchen unit that reaches the floor with no air gap cannot dissipate heat, so film under it would overheat and the floor would not benefit. Stop the strips at the unit face and hold the standard edge gap. Do not run film through the footprint and assume it will be fine.
Furniture with a raised base. A unit on legs with a clear gap, usually at least a few centimetres, lets heat escape and can be heated normally. Check the actual clearance before deciding. A sofa on tall legs is a heated zone; a floor-mounted cabinet is not.
Sanitaryware and wet fittings. Baths, shower trays, and floor-mounted toilets are excluded. The strips in a bathroom are cut to fit the open floor only, and the wet-room build uses the sealed encapsulated film rather than open stock.
Floor openings and registers. Drains, floor vents, access panels, and the base of a soil pipe all break the strip. Cut the strip to finish before the opening rather than notching around it; notched narrow strips are fragile and hard to seal.
When the fixed objects are marked first, the strips almost always fall into straight runs with clean ends. When they are ignored, the installer discovers them mid-cut and the layout fills with short filler pieces that add cold leads without adding useful coverage.
Spacing between strips and edge gaps
Strips are laid with deliberate gaps, and these gaps are part of the design rather than a sign of incomplete coverage.
Gap between strips. A narrow channel of a few centimetres separates adjacent strips. It gives the floating floor a flat surface to sit on, prevents the PET edges from riding up, and provides a channel for the cold leads. The exact gap follows the product installation guidance and the floor type.
Edge gap to the wall. The outer strips hold back from the wall by the standard expansion gap, which is the same gap the floating floor needs to move. The film does not run tight to the skirting. This gap also hides the cold-lead channel where the wires turn up toward the thermostat.
Coverage versus gap. Buyers sometimes assume the gaps mean unheated cold bands. They do not. The heat spreads laterally across the floor, and the finish above the gap reaches nearly the same temperature as the finish above the film. The strips are sized so the gap stays well within the comfort range, rather than spaced so wide that a cold stripe appears.
Even spacing matters more than tight spacing. Uniform gaps give uniform floor temperatures. A layout with one wide gap and several tight ones will show as a faint stripe under a sensitive wood floor. Mark the gaps on the subfloor rather than judging them by eye.
Cold-lead side and routing the wires back to the wall
Every strip has a working end where the cold lead connects, and the layout has to point all these ends toward a route the wires can actually follow. This is the part of the plan that is easiest to forget and the most painful to correct.
Set the cold-lead side first. The strips should be oriented so their cold-lead ends face the wall that holds the thermostat or the junction box. In a simple room all the cold leads finish on the same wall, which keeps the wiring short and the channels hidden under one skirting run.
Run the leads in the edge channel. The cold leads lie flat in the gap between the outer strip and the wall, or in the inter-strip channels, and turn up at the thermostat position. They should not cross under a strip where a wire could be pinched by the floor.
Count the leads against the control. Each strip adds a pair of cold leads. The total number of strips has to be matched to the thermostat’s switch capacity or split across a contactor and multiple zones. A wide room that looks simple on film count can exceed a single 16 A thermostat once the loads are added.
Plan the junction points. Where several strips meet in one zone, decide where the parallel connections happen before laying them. A drawn junction point keeps the wiring tidy and avoids a tangle of terminals tucked under the floor with no room to service them.
The cold-lead plan is closely tied to the electrical wiring topology, which is treated in its own guide. For the layout, the rule is simple: decide the lead side early, keep every lead in a marked channel, and never let a strip finish where its wire cannot reach the wall.

Worked example: a 16 m² bedroom, strip by strip
Here is the method applied to a real shape. The room is a 4.0 m by 4.0 m bedroom with a built-in wardrobe 1.8 m wide on one wall and the thermostat on the wall opposite the window.
Step 1 — find the heated footprint. The wardrobe removes a strip of floor, so the heated area is the room minus the wardrobe footprint. The bed sits on legs and stays in the heated zone. The usable heated footprint comes out around 13.5 m² rather than the full 16.
Step 2 — pick the width. The strips cross the short dimension toward the thermostat wall. A 50 cm film divides the span cleanly, with the edge gaps and the inter-strip channels accounted for. A 100 cm roll would leave a wide remainder, so the 50 cm width is chosen.
Step 3 — set the cut lengths. The full-length strips run toward the window wall and are cut at the nearest mark covering the run plus the edge gap. The strips that meet the wardrobe are shorter and cut at a lower mark, stopping at the wardrobe face with the standard gap.
Step 4 — mark the gaps. The inter-strip channels and the wall edge gaps are marked on the subfloor before the film goes down, so every strip lands in a measured position rather than being nudged by hand.
Step 5 — route the cold leads. All the cold-lead ends point to the thermostat wall and run in the edge channel, turning up at the single control position. The strip count is checked against the thermostat load, and a contactor is added if the current exceeds the switch rating.
The result is a cut sheet with every strip named by width, cut length, and position, a waste share inside the target band, and no film trapped under the wardrobe. The same five steps repeat in every room; only the dimensions change.
The pre-inquiry layout checklist
Fill this in before the specification call and the cut sheet comes back right the first time. These are the facts the factory needs to produce a layout rather than a generic roll length.
- Real wall dimensions, measured in the room, including alcoves and any out-of-square diagonal.
- The footprint of every fixed object: cabinets, sanitaryware, islands, and floor openings, with which ones reach the floor.
- The heated footprint kept separate from the total room area.
- The wall that will hold the thermostat and the route the circuit enters the room.
- The available floor build height, especially for a retrofit over an existing floor.
- The floor finish and whether it is a floating dry floor or a glued build.
- The market and supply voltage, including the country, so the correct film build is made.
- Whether the room is a wet area, which forces sealed film and an RCD.
Common layout mistakes
These are the errors that turn a measured job into a return visit with the floor already down.
Ordering film on total room area. The heated footprint is smaller than the room once fixed objects are removed. Ordering on the full area leaves surplus film and tempts the installer to run strips under cabinetry to use it up.
Defaulting to the widest roll. A 100 cm film in a narrow room creates a long off-cut and stiff, awkward strips. Width is matched to the span, not chosen for its headline number.
Cutting freehand instead of on the marks. A cut across the printed heating pattern opens a live path and destroys the strip. Every cross-cut is on a printed line and every lengthwise trim is forbidden.
Running strips under full-base units. Film trapped under a floor-mounted cabinet overheats with no way to dissipate. Strips stop at the unit face, even if that leaves a short run.
Forgetting the cold-lead side. Strips laid with their working ends pointing away from the thermostat force long wire runs and visible channels. The lead side is decided before the first strip is placed.
Judging gaps by eye. Uneven gaps produce uneven floor temperatures and can show as stripes under wood. Mark every channel on the subfloor.
Ignoring the control load. A room full of strips can exceed one thermostat. Count the load against the switch rating and add a contactor or split the zones rather than overloading a single control.
Data and evidence: where the numbers come from
The layout figures here are built from three sources. Dry-floor and radiant heating installation guidance sets the approach to strip spacing, edge gaps, and the treatment of fixed furniture and floating floors. The printed cut-mark system and the twelve-width range come from the way the film is manufactured and marked on the line. SunAura factory cut records supply the product facts: the standard widths from 10 to 100 cm, the stepped cut lengths, the PET carrier with printed heating zones and running copper busbars, and the waste shares that result from a planned cut sheet rather than a freehand job.
The factory has produced heating elements since 2008 and runs the film lines under ISO 9001 quality management, with CE and RoHS documentation issued with shipments. The exact cut-mark spacing and gap dimensions should always be confirmed against the installation guidance for the specific product line, because they can vary between builds.
Frequently asked questions
Can I just order the film by room area and cut it to fit on the day?
No. The heated footprint is smaller than the room, and the cut lengths are stepped. Plan the strips against the real floor plan first, or you will waste film and risk cutting across a live path. A drawn cut sheet is faster than fixing it under a finished floor.
What happens if a strip comes up slightly short of the far wall?
A short strip leaves a cold band at the edge. Always choose the cut mark that is not shorter than the run, and manage any extra length against the wall gap. You cannot extend a strip once it is cut.
Do the gaps between strips make the floor feel cold?
No. The heat spreads laterally through the floor finish, and correctly spaced gaps stay within the comfort range. It is wide, uneven gaps that cause stripes, not the narrow marked channels in a planned layout.
Can I trim the film width to make a strip fit?
No. The long edges carry the busbars, and a lengthwise cut opens them. Width is fixed at manufacture; if a strip does not fit, use a narrower standard width rather than trimming a wide one.
How do I handle a room where the cold leads cannot all reach one wall?
Split the room into zones, each with its own lead side and junction point, rather than forcing long runs across the floor. Mark the junction positions early and check the extra load against the controls.
Is a wider film always more efficient because it has fewer joints?
Not in every room. Fewer joints help in a large open space, but a wide film in a narrow room produces a large off-cut and harder handling. Match the width to the span and the waste falls on its own.
Final recommendation: how to plan the strips
The layout collapses to a clear sequence. Measure the real room, mark every fixed object, and shade the heated footprint before opening a roll. Choose the width that divides the short span with the smallest remainder, even when that means a narrower film rather than the widest one. Cut every strip only on the printed marks, hold the measured inter-strip and edge gaps, and orient every cold-lead end toward the wall that holds the control. Name each strip by width, cut length, and position on a cut sheet, and check the total load against the thermostat before ordering. Follow that order and the aluminum film mat or the custom encapsulated film slots in only where the build genuinely needs it, the waste stays inside the target band, and the floor goes down over a layout that will not need lifting.