Here is the short answer buyers need before they order a heating film: the voltage does not change how warm a correctly sized floor gets, but it changes almost everything about the wiring, the breaker, the thermostat and the copper you have to pay for. Pick the voltage that matches the building’s supply, and when a transformer gives you a choice, the higher voltage wins on almost every electrical count. This guide works through why a 110 V film draws roughly twice the current of a 220–230 V film for the same heat, what that does to circuit design, and how to specify the right build without guessing. Every film figure ties back to the builds on the SunAURA heating film product page.
Why voltage is a wiring decision, not a comfort decision
A graphene-carbon heating film is a resistive load. It does not care which voltage pushes the current, within its rated range. What it cares about is the power it has to dissipate, measured in watts per square metre. The product page lists the same far-infrared technology across its 110 V and 220–230 V builds, with the same printed carbon tracks, the same PET carrier and the same floor surface temperature of about 27–28 °C under thermostat control. A 150 W/m² floor is a 150 W/m² floor on either voltage.
The difference sits in a basic relationship: power equals voltage times current. Hold the power constant and halve the voltage, and the current has to double to deliver the same watts. That single fact drives the rest of the electrical design. A 10 m² room at 150 W/m² needs 1,500 W. On 230 V it draws about 6.5 A; on 110 V the same 1,500 W pulls close to 13.6 A. Same heat, double the amps. Every component that carries those amps has to be sized for them.
This is why voltage should be treated as a circuit-design and procurement question rather than a comfort feature. The room feels identical. The bill of materials, the breaker panel and the thermostat rating do not.

Where each voltage is actually used
The first constraint is not a choice at all. Most buildings have a fixed nominal supply, and the film should be ordered to match it so it runs directly without a transformer.
- 220–230 V regions. Most of Europe, the UK, China, Australia, New Zealand, large parts of Asia and Africa run 220–240 V single-phase. The 220–230 V film connects straight to the ring or radial circuit through the thermostat.
- 110–120 V regions. North American homes commonly supply 120 V at the wall even though 240 V is available at the panel for large appliances. A 110–120 V film suits rooms that will run on a standard branch circuit. Where the load is large, a dedicated 240 V circuit is often the better route.
- Japan. The nominal supply is 100 V (50 Hz in the east, 60 Hz in the west). A film built for the Japanese market is rated around that supply; the product page’s 110 V build covers the region, and the frequency does not affect a resistive heater.
- Off-grid, RV and marine. These often use 12 V or 24 V DC through an inverter or a dedicated low-voltage film, a separate case covered in the low-voltage heating film guide. This article stays with the 110 V and 220–230 V mains builds.
When the building already provides the voltage, the decision is made. The real engineering questions start when a project has access to both voltages at the panel, or plans to use a transformer to step the supply up or down.
The current comparison, with real numbers
The table below applies the same heated areas and power densities to both voltages and shows the resulting current. Figures use simple power-over-voltage maths and the density bands on the product page; they ignore small power-factor effects because a resistive heater has a power factor near unity.
| Heated area & density | Total power | Current at 230 V | Current at 110 V | Practical effect |
|---|---|---|---|---|
| 5 m² at 150 W/m² | 750 W | 3.3 A | 6.8 A | Both fit a small branch; 110 V leaves little spare on a 10 A fuse |
| 10 m² at 150 W/m² | 1,500 W | 6.5 A | 13.6 A | 110 V needs a 16 A breaker; 230 V sits comfortably on 10 A |
| 15 m² at 180 W/m² | 2,700 W | 11.7 A | 24.5 A | 110 V exceeds a 20 A branch and needs a 25–32 A circuit or a split |
| 20 m² at 200 W/m² | 4,000 W | 17.4 A | 36.4 A | 110 V is impractical on one circuit; split zones or use 230 V |
Read down the 110 V column and the limit appears quickly. A modest bathroom or kitchen is fine, but an open living area at retrofit density pushes past the current that a normal 15–20 A branch can carry. The 230 V column stays inside a single modest circuit for the same room. This is the core reason higher voltage is preferred for large heated areas: the current, not the heat, is the constraint.

What the higher current does to cable and breaker sizing
Once the current is known, four parts of the installation have to be re-sized for the 110 V build.
- Circuit conductors. A cable’s safe current is set by its cross-section and how it is installed. Because the 110 V film carries about twice the amps, the supply cable may need a larger cross-section to stay within its temperature limit and to keep voltage drop low. On 230 V the same load often uses a smaller conductor.
- Overcurrent protection. The breaker or fuse must carry the running current plus the normal margin, typically sized so the continuous load does not exceed about 80% of the breaker rating. A 13.6 A load points to a 16–20 A breaker; the 230 V equivalent needs only 10 A. The heating film parallel circuit guide covers how to split large loads across several protected circuits.
- Voltage drop. Voltage drop along a cable is current times resistance. Double the current and the drop doubles for the same cable. On long cable runs from the panel, a 110 V system loses a larger share of its already lower voltage, which can leave the far end of the film under-powered. Shorter runs or larger conductors fix it, both at a cost.
- Joints and terminals. Every connector, terminal block and cold-lead joint has a current rating. Higher current heats the joints more, so the specified terminals have to be rated for the 110 V amps rather than the smaller 230 V figure.
The cost pattern is consistent. The film element is priced by area and is similar either way, but the 110 V project can carry extra cost in copper, breakers and terminals. On a large floor that extra material is real money, which is why a North American project with a heavy load often runs a dedicated 240 V circuit instead of spreading the load across 120 V branches.
The thermostat and contactor limit
A floor heating thermostat does not just read temperature. It switches the load through an internal relay, and that relay has a hard current ceiling. The product page’s controls span direct-switching relays at 16 A with 20 A and 25 A versions, alongside contactor-based arrangements for larger systems.
At 230 V, a 16 A relay can switch roughly 3.6 kW, enough for many rooms directly. At 110 V the same 16 A relay switches only about 1.76 kW before it reaches its current limit, even though the relay itself is rated for the same amps. The voltage does not change the relay’s amp rating; it changes how much heating power those amps represent. A 110 V room that would be a simple direct-switch job on 230 V can therefore need an external contactor controlled by the thermostat, or a split into two circuits.
The rule is to size the switching device from the current, never from the watts alone. Work out the amps at the actual project voltage, then check whether the thermostat’s relay covers them with margin. If it does not, specify a contactor. The thermostat load and contactor guide walks through the arithmetic. Specifying a contactor after the wall is finished is far more expensive than planning it on the panel schedule.

When a transformer enters the design
Some projects cannot match the film directly to the supply. A building with a 230 V supply but 110 V equipment, an industrial site with an unusual voltage, or a customer who has already bought a film at the wrong voltage may introduce a step-down or step-up transformer. Three rules keep this honest.
Rate the transformer on apparent power, with margin. The transformer has to cover the total film load plus a safety margin, commonly 20–25%, because a heating film is a continuous load that may run for hours. A 3 kW film should not hang on a 3 kVA transformer with no headroom. The transformer also has its own losses, which appear as heat and a small standing consumption.
Account for the transformer’s inrush and protection. When a transformer energises it draws a short magnetising inrush, and the upstream breaker must be chosen to ride through it while still protecting the circuit. The film side and the supply side need separate overcurrent protection because the currents differ.
Prefer matching the film to the supply. Every transformer adds cost, a point of failure, efficiency loss and bulk. If the project is still at the specification stage, ordering the film at the building’s native voltage is almost always cheaper and introduces fewer failure points than transforming the supply. Transformers are a solution for a fixed constraint, not a default design.
What happens if the wrong-voltage film is connected
Because a film is a fixed resistive element, its resistance does not change with the supply. The power it produces follows voltage squared over resistance, and that squared relationship makes a wrong-voltage connection severe in both directions.
Connect a 220–230 V film to a 110 V supply and the power does not halve; it falls to roughly a quarter, because the voltage ratio is about one half and that ratio is squared. A sheet designed for 150 W/m² delivers somewhere near 35–40 W/m². The floor may feel faintly warm near the panel but never reaches its design temperature, and the thermostat will keep calling for heat without getting there. It is not a fault that can be tuned out; the element is simply the wrong build for the supply.
The reverse is more dangerous. Put a 110 V film on a 220–230 V circuit and the power jumps to roughly four times the design value. The carbon tracks cannot dissipate that heat, the PET carrier can overheat and shrink, and the element can fail or trip the protection within a short time, sometimes on the first warm-up. This is why the film’s rated voltage must be checked against the measured supply before energising, and why a customer who has stock bought for one region should not assume it will work at a different voltage.
The practical procurement rule is simple: the rated voltage printed on the film and its datasheet must match the building supply, not merely overlap it. There is no harmless “close enough” voltage on a resistive heater, because the error is squared rather than linear. Confirming this one field at goods-in avoids both a permanently cold floor and a destroyed element.
The safety myth around the lower voltage
Buyers sometimes assume 110 V is meaningfully safer than 230 V and specify it for that reason. The instinct is understandable but the conclusion is wrong for a mains-connected film. Both 110 V and 230 V are well above the voltage that can drive a dangerous current through the human body, and both are capable of causing serious shock. Neither is a separated extra-low voltage; the genuinely low-voltage safety category starts at the 12 V and 24 V SELV builds, which are a different product.
Real safety comes from the same measures regardless of which mains voltage is used: a properly rated RCD or GFCI that disconnects on earth leakage, the shielded and double-insulated construction noted on the product page, correct earthing, and the IP67 encapsulation in wet rooms. The page lists the film as EMF-shielded and IP67 for the encapsulated build. Specifying 110 V for imagined safety does not replace any of these, and it should not be used as a reason to skip them.

Scene-by-scene voltage selection
Small bathroom or kitchen on a 120 V supply. A 5–8 m² heated area at 160–180 W/m² stays within a dedicated 15–20 A branch. Use the 110 V film on its own circuit with GFCI protection and the encapsulated build for the wet floor. Confirm the branch does not share large loads.
Open living area in a 120 V home. Once the load approaches 2 kW, the current clears a normal 20 A branch. The cleaner route is a dedicated 240 V circuit from the panel using a 220–230 V film, which keeps the current around half and lets one thermostat switch the room. If only 120 V is available, split the floor into two zones on separate breakers.
European or Asian new build at 230 V. Specify the 220–230 V film directly. The lower current keeps cable and breaker sizes modest, and a 16 A thermostat covers a typical room without a contactor. This is the lowest-cost electrical arrangement for a given heated area.
Japanese retrofit at 100 V. Use the 110 V-rated film matched to the 100 V supply and size the branch to the local rules; the slightly lower nominal voltage means the current is a touch higher than a 110 V calculation suggests, so confirm the breaker margin on the actual nameplate.
Large commercial floor. Even where 110 V exists locally, the panel almost always provides a higher voltage. Run the film zones on the higher voltage to keep each circuit’s current and voltage drop manageable, and use contactors where the zone exceeds the relay. Fewer high-current circuits mean fewer heavy cables and fewer failure points.
Pre-order checklist: the parameters to confirm
Send these fields to the supplier before the film is cut, and get the answers in writing. They prevent the most common voltage-related rework.
- The exact nominal supply voltage and frequency at the building, measured rather than assumed.
- Heated area and the chosen power density (roughly 100 W/m² ceiling, 100–150 living, 180–200 cold bath or retrofit), so total power is known.
- The calculated running current at that voltage, and the proposed breaker rating with the continuous-load margin.
- The supply cable cross-section and the maximum cable run length, checked for voltage drop.
- Whether the thermostat’s relay switches the load directly or an external contactor is required.
- If a transformer is unavoidable, its kVA rating, efficiency and the protection on both sides.
- The protection build for the room: IP67 encapsulated and shielded for wet duty, dry standard film only where appropriate.
Common selection mistakes
Buying by watts and ignoring amps. Two films with the same wattage behave very differently at the breaker. Always convert the load to current at the actual voltage before choosing the circuit.
Ordering the wrong voltage and planning to “fix it with a transformer”. That fix adds cost and losses for the life of the system. Matching the film to the native supply at the order stage is cheaper on every project.
Assuming the thermostat rating is universal. A relay rated 16 A switches half the watts at 110 V that it does at 230 V. Check the amps against the real voltage.
Treating 110 V as safe extra-low voltage. It is still a mains voltage and needs full RCD, earthing and wet-area protection.
Running long 110 V cable without a drop check. The doubled current makes voltage drop bite harder; the far end of the floor can under-heat even when the panel is correct.
Data and evidence: what the standards and engineering data say
The relationship between voltage, current and power is not a manufacturer claim; it is Ohm’s and Joule’s law applied to a resistive load, and it is the basis of every electrical code. Wiring standards set current-carrying capacities for conductors and require overcurrent devices to protect those conductors, which is why the doubled current at the lower voltage forces larger components. Building electrical rules also require residual current protection and define continuous-load derating, typically expecting a device to carry no more than about 80% of its rating on a sustained load such as heating film.
On the heating side, radiant floor standards such as the EN 1264 series define floor surface temperature limits and the use of control sensors; the roughly 27–28 °C controlled floor surface sits within that framework regardless of the supply voltage. Energy and building research consistently treats the supply voltage as an efficiency-of-distribution question: higher-voltage distribution reduces current and resistive losses, the same reason grids transmit at high voltage. None of these sources change the comfort output of a correctly sized film; they confirm that the voltage decision lives in the distribution design, not in the radiant surface.
The factory facts stay within their documented bounds: SunAURA was established in 2008 and has built heating elements for seventeen years, holds ISO 9001 and 14001 management systems alongside CE and RoHS documentation, and runs its own quality laboratory where circuit resistance and protection are checked. No specific certificate number, test figure or customer name is invented here; the product-specific ratings should be confirmed against the live product page and the quotation.
Final recommendation
Specify the voltage in this order. First, match the film to the building’s native supply so no transformer is needed. Second, where the panel offers a choice and the heated area is large, take the higher voltage because it halves the current, shrinks the cable and breaker, limits voltage drop and lets the thermostat switch the load directly for longer. Third, reserve the 110 V build for smaller rooms and regions where that is the supply, and split the floor into protected zones rather than overloading a single branch. Fourth, size every conductor, breaker, relay and possible transformer from the calculated amps at the real voltage, with a documented margin. Follow that sequence and the room delivers the same even far-infrared warmth either way, while the electrical design stays safe, efficient and within code.
For the full set of available builds and their current ratings, work from the heating film applications hub and the live product page, and confirm the final figures in the written quotation.