The short answer: heat trace is sized to replace the heat a pipe loses through its insulation, not to heat the pipe to a high temperature, and the correct output depends on three things together, pipe diameter, insulation thickness and the difference between the temperature you must hold and the coldest ambient. Two pipes with the same diameter can need different cables if one is better insulated or exposed to a colder climate. This guide works through the heat-loss logic, gives a DN20 to DN150 sizing table with the real output bands, and explains where the 10–20% safety margin and the extra cable for valves and flanges fit. All figures come from the SunAURA heat trace cable product page.
What heat trace actually has to do
An insulated process pipe or water line still loses heat to the surrounding air. Insulation slows that loss but does not stop it. The job of the trace cable is to put back, metre for metre, the heat that escapes so the pipe contents stay at the temperature the process needs. For a freeze-protection line that means holding above freezing; for a viscous product such as oil, wax or syrup it means holding a higher maintenance temperature so the fluid keeps flowing.
This is a balance, not a heating race. If the cable output matches the heat loss, the pipe holds a steady temperature. If the output is too low, the pipe cools until the contents freeze or thicken. If it is far too high, energy is wasted and local temperatures can climb. The whole sizing exercise is a heat-loss calculation that ends in a cable whose rated output covers the loss with margin.

The three inputs that drive the heat loss
- Pipe diameter. A larger pipe has more outside surface per metre, so it presents more area for heat to escape. Diameter sets the base surface area in the loss calculation, which is why the sizing table is grouped by nominal pipe size.
- Insulation thickness and type. Thicker insulation, or insulation with a lower thermal conductivity, raises the resistance to heat flow and cuts the loss. The reference table assumes 30 mm insulation; a thinner or wet insulation raises the real loss, and a thicker one lowers it.
- Temperature difference. Heat flows faster when the gap is wider. The relevant difference is between the maintenance temperature and the lowest expected ambient. A line held at 5 °C against a -20 °C winter sees a 25-degree difference; the same line held at 40 °C sees a 60-degree difference and loses far more heat.
These three are not independent choices. The designer fixes the maintenance temperature from the process, takes the minimum ambient from local climate data, knows the pipe size from the mechanical drawings, and selects the insulation. Only then can the heat loss in watts per metre be read or calculated. Sizing from diameter alone, ignoring insulation or climate, is the most common cause of an under-powered trace.
The DN20 to DN150 heat-loss reference table
The table below is the product page’s reference for heat loss at a -20 °C minimum ambient with 30 mm insulation, grouped by nominal pipe size. Treat it as a starting reference; the actual project figures should be confirmed against the real insulation and design temperatures.
| Nominal pipe size | Heat loss range (W/m) | Typical cable choice | Notes |
|---|---|---|---|
| DN20–DN25 | 12–18 | 16 W/m PTC or 25 W/m constant | Small bore, low surface area; freeze protection common |
| DN32–DN50 | 18–26 | 30 W/m PTC or 25–40 W/m constant | Mid-size process and water lines |
| DN65–DN100 | 26–38 | 30–45 W/m PTC or 40 W/m constant | Larger surface; higher maintenance temperature pushes output |
| DN150 and above | 38–55 | 45 W/m PTC or 50 W/m constant | Large bore; long runs may use three-phase power |
| Tanks and vessels | 30–60 W/m² | Selected by surface area | Area-based rather than linear loss |
The ranges rather than single values reflect the temperature difference. A DN50 line held just above freezing sits at the low end of its band; the same pipe holding a hot process fluid sits at the high end. Once the loss is read, the cable’s rated output at the maintenance temperature must meet or exceed it, and the margin is then added on top.

How to apply the 10–20% safety margin
The product page calls for a 10–20% margin on top of the calculated loss, and there are concrete reasons it exists rather than being a round number. Insulation can be damaged, damp or thinner than specified; doors and valves interrupt the insulation; voltage can sit slightly low; and the coldest ambient in a long service life can exceed the design value. The margin keeps the cable effective when the real installation is less perfect than the calculation.
Apply it as a multiplier. If a DN80 line works out to 32 W/m of loss, a 20% margin raises the requirement to about 38 W/m, pointing to a 45 W/m PTC cable or a 40 W/m constant build depending on the control approach. The margin is added to the loss, not to the cable rating, and it should not be used to justify a cable that is oversized by a large factor, which wastes energy. Where the insulation is known to be poor or the duty is critical, lean toward the 20% end; on a well-insulated, well-documented line, 10% is reasonable.
A worked example on an oil line
Take a DN65 steel pipe carrying a fuel oil that must be held at 30 °C to stay pumpable, at a site where the design minimum ambient is -20 °C and the line is covered with 30 mm insulation. The temperature difference is 50 degrees. From the reference table, DN65–DN100 losses run 26–38 W/m; a line held well above ambient at a wide difference sits toward the upper part, so the loss is taken at about 35 W/m.
Adding a 20% margin because the line runs outdoors and the insulation is weather-exposed gives 35 times 1.20, or 42 W/m. A 45 W/m PTC cable covers this, but the check has to confirm that at the 30 °C maintenance temperature the self-limiting cable still delivers at least 42 W/m; if its output has fallen below that by the time it is warm, the next step is either the 50 W/m constant-wattage cable or a higher PTC rating. The constant 50 W/m build on a thermostat is the simpler choice where the warm-output margin is tight.
For a 60 m run with three gate valves and six flanges, the straight requirement is 60 m plus the per-component extra allowance for those valves and flanges, and the total circuit load is checked against the maximum single-phase circuit length. If the run is too long for one circuit, it splits into two 30 m circuits, and where the total power is high it moves to 400 V three-phase. The example shows the same derived logic as the indoor cases: loss, margin, warm-output check, component allowance and circuit limit, in that order.
PTC self-limiting and constant-wattage builds
The page lists two families. The PTC self-limiting cables come in 16, 30 and 45 W/m nominal outputs, and their real output falls as the cable warms, so the rating that matters for sizing is the output at the maintenance temperature, not the cold-start number. They resist overheating and suit most pipe freeze and temperature-maintenance duties. The constant-wattage silicone cables come in 25, 40 and 50 W/m and give a steady output, which suits long runs and high-temperature maintenance where a predictable output is wanted, controlled by a thermostat.
Because a PTC cable’s output is highest when cold and declines as it warms, the sizing check has to confirm that at the maintenance temperature it still delivers enough to cover the loss. A nominal 30 W/m PTC may deliver less than 30 W/m once the pipe is warm. The constant-wattage cable is simpler on that count because its output is fixed, but it depends entirely on the control system to avoid overheating. The heat trace versus constant-wattage guide compares the two in detail.
Start-up, voltage and long circuits
When a PTC trace is first energised on a cold pipe, every metre draws its maximum cold-start output at once, producing an inrush that settles as the cable warms. The breaker must be sized to ride through this start-up current rather than the lower steady figure, a point covered in the heat trace start-up current guide. Ignoring it gives nuisance trips on cold mornings even though the running load is fine.
The supply voltage is 230 V single-phase for most shorter runs, with 400 V three-phase available for long, high-power circuits where the total load would be awkward on one phase. Splitting a long line into several circuits, each with its own protection and connection, keeps each run within the breaker and cable-length limits. The page specifies an IPX8 build on a 30 mA RCD, which is the required protection for a cable mounted on metal pipework. Maximum circuit lengths from the manufacturer data should be respected rather than extended, because the voltage drop and the start-up current both grow with length.

Control strategies: ambient sensing, line sensing and self-limiting
How the trace is switched affects both energy use and sizing confidence. Three approaches are common. A simple ambient thermostat energises the cable when the surrounding air falls below a set point, which is cheap and adequate for basic freeze protection but runs the cable whenever the air is cold even if the pipe does not need it. A line-sensing thermostat measures the pipe surface directly and holds the maintenance temperature more tightly, suiting process lines where the temperature matters. A proportional or controller-based system modulates or cycles the output against a sensor, giving the closest control on critical or high-temperature duties.
A self-limiting PTC cable can in principle run without a thermostat because it reduces its own output, but adding a control still saves energy and gives a measurable temperature, and most specifications require a switch and indication regardless. The choice of control should be made at the sizing stage because it affects which cable family is appropriate: a constant-wattage cable always needs a line-sensing controller, while a PTC build is more forgiving of a simpler ambient switch. Specifying the control up front also means the sensor and the connection points are placed before the insulation is closed, where they are easy to reach.
Valves, flanges, pumps and supports: the extra cable
The linear loss table covers the straight pipe, but a real line has components that interrupt the insulation and lose more heat per metre. Valves, flanges, strainers, pump bodies and pipe supports each need extra trace length coiled or wrapped around them, because their irregular shape and thinner insulation create local cold points. The cable is never cut to make this length; the designer adds the recommended extra length per component when the total cable quantity is calculated.
This extra is easy to miss on a first takeoff and it is why the cable order rarely equals the simple pipe length. A common method is to total the straight-metre requirement from the loss table, then add the per-component allowances for every valve and flange on the line, and confirm the connection kit and end seals match. The mechanical components also need the cable routed so it can be removed for maintenance without damage, with the trace fixed to the lower side of the pipe rather than underneath it where it can be pinched. The heat trace installation guide covers the routing and component allowances.
Why insulation condition is part of the cable decision
The trace and the insulation work as a pair, and a cable sized for dry, intact 30 mm insulation can be under-sized the moment that insulation gets wet, compressed or removed. Water inside the insulation raises its effective conductivity sharply, so an outdoor line with a failed weather seal loses far more heat than the table assumes. Mechanical damage around supports and foot traffic can also compress the insulation to a fraction of its thickness, creating local high-loss spots.
This is why the margin is not optional on exposed outdoor lines and why the insulation system, including its vapour barrier and outer cladding, should be specified alongside the cable rather than treated as a separate trade. On lines that are difficult to access after commissioning, leaning toward the higher output and the full 20% margin is the defensible choice. During service life, the trace should be checked whenever the insulation is repaired, and any section that has been wet should be dried or replaced before the cable output is assumed adequate. Treating the insulation as a maintained component, rather than a one-time fit, keeps the original heat-loss calculation valid for the life of the line.
When you take over an existing line, treat the insulation as unknown until it is inspected rather than trusting the nominal thickness on old drawings. The cladding may look sound while the material underneath has settled, absorbed water or been cut away at earlier repairs. A short survey of a few representative sections, plus a check of the outdoor weather seals, gives a far safer basis for the cable rating than the paperwork alone. If the insulation cannot be confirmed, the prudent move is to size to the higher output and the full margin, because the cost of a marginally larger cable is small against the cost of a frozen or stalled process line.
Scene-by-scene sizing
Small water pipe, freeze protection. DN20–DN25, held just above freezing against a cold winter, lands in the 12–18 W/m band. A 16 W/m PTC cable with a 10–20% margin covers it, switching on a thermostat or ambient sensor. This is the simplest and most common duty.
Mid-size process line, moderate temperature. DN32–DN50 holding a viscous product at a maintenance temperature well above ambient moves up the loss band. A 30 W/m PTC or 25–40 W/m constant cable, checked at the maintenance temperature, keeps the fluid moving.
Large bore or high-temperature line. DN100–DN150 with a wide temperature difference reaches 38–55 W/m. Use the 45 W/m PTC or 50 W/m constant build, add the full 20% margin, and plan three-phase power and split circuits for long runs.
Tank or vessel. Switch from linear to area logic, sizing the cable against the 30–60 W/m² tank loss over the surface area, with extra attention to the base and any supports where heat escapes.
Hazardous or explosive area. If the line carries a flammable fluid in a classified zone, the cable and connections must meet the customer’s specified certification for that area. The page does not claim a specific ATEX rating, and none should be invented; the correct certified build is supplied against the documented area classification rather than assumed.
Pre-order checklist
- Maintenance temperature the process requires, and the minimum design ambient for the site.
- Pipe material and nominal diameter for every section, plus the total straight length.
- Insulation type, thickness and conductivity, and whether it is weather-sealed outdoors.
- The calculated heat loss in W/m, confirmed against the reference table or a full calculation.
- The cable family and output that covers the loss after a 10–20% margin, checked at the maintenance temperature.
- Extra cable length for every valve, flange, pump and support, plus connection and end-seal kits.
- Supply voltage and phase, the breaker sized for cold-start inrush, and the 30 mA RCD and IPX8 protection.
- For classified areas, the exact certification the customer requires before any cable is specified.
Common sizing mistakes
Sizing on diameter alone. The same pipe loses different heat depending on insulation and temperature difference; all three inputs are needed.
Using the PTC nominal output as its warm output. A self-limiting cable gives less once warm; confirm the output at the maintenance temperature covers the loss.
Forgetting the start-up inrush. Breakers sized only to the steady load trip on cold energising.
Ignoring valves and flanges. These cold points need extra cable length; a straight-pipe-only order comes up short.
Skipping the margin or over-sizing wildly. No margin leaves no room for real-world insulation faults; a vastly oversized cable wastes energy and can overheat.
Assuming a hazardous-area rating. Certification must match the documented area classification and should never be guessed.
Data and evidence
Heat-loss sizing for traced lines follows steady-state heat-transfer methods: the loss through cylindrical insulation is a function of the pipe surface area, the insulation conductivity and thickness, and the temperature difference, which is the same physics used in mechanical and process engineering standards. Industry trace-design guides and insulation manufacturers publish heat-loss tables by pipe size and insulation thickness against design ambient, the basis of the reference ranges given here. Electrical rules set the residual-current requirement, the IPX8 protection and the need to size overcurrent devices for the cold-start inrush of self-limiting cables.
The use of a safety margin is standard practice in process heating because installed insulation rarely matches the ideal calculation and design ambients can be exceeded. For the broader freeze-protection case, building and energy research in cold climates treats pipe temperature maintenance as an energy balance rather than a fixed heating load, supporting the loss-based approach. On the manufacturer side, SunAURA has built heating elements since 2008, runs ISO 9001 and 14001 systems with CE and RoHS documentation, and the self-limiting builds carry a 15–25 year service window; the EXW price band for trace runs roughly US$1.50–8.00 per metre depending on the family and output. No certificate number, customer name, test figure or hazardous-area rating is invented, and the live product page should be used for confirmed figures.
Final recommendation
Size the trace in this order. Fix the maintenance temperature and the minimum ambient, identify the pipe size and the actual insulation, and read or calculate the heat loss in W/m. Add the 10–20% margin, then select a PTC or constant-wattage cable whose output at the maintenance temperature covers the grossed-up figure. Add the extra length for valves, flanges and supports, choose the voltage and phase for the run length, and size the breaker for the cold-start inrush on an RCD-protected, IPX8 circuit. In classified areas, build to the customer’s stated certification rather than assuming one. Follow that sequence and the line holds its design temperature through the coldest conditions without wasting energy or developing local cold points.