The short answer: a heating mat is sold by the area it covers, and the right kit is the one whose rated area matches the usable floor you actually heat, not the gross room size. The cable is pre-spaced on a mesh at a fixed output, so unlike loose cable you do not choose the spacing on site; you choose the kit size and the correct wattage for the floor finish. This guide explains how to measure for a mat, what the 150, 160 and 200 W/m² builds are each for, why the heating cable can never be cut even though the mesh can, and how to handle irregular rooms and multiple circuits. Every figure comes from the SunAURA heating mat product page.
What a mat fixes for you, and what it does not
A heating mat takes the cable-spacing decision out of the installer’s hands. The resistance cable is already taped to a self-adhesive mesh at a set spacing, which locks in the area output and the evenness. The mat is 0.5 m wide and only about 3.6 mm thick, so it adds almost no floor height, which is the main reason it is used in retrofits and under thin tile builds. You unroll it, stick the mesh down, and the spacing is correct from the first metre.
What the mat does not fix is the area planning. The cable length and the mesh area are fixed for each kit, so the kit has to be selected to cover the real heated area. Choose too small a kit and part of the floor stays cold; choose too large and there is nowhere to put the surplus without overlapping, which is not allowed. The convenience of pre-spacing is paid for in the need to size the kit accurately before ordering.

Measure the usable area, not the room size
The single most important measurement is the usable heated area, which is almost always smaller than the room’s gross floor area. Subtract the footprint of anything fixed that sits on the floor and should not be heated: kitchen cabinets and plinths, the bath and shower tray, the toilet base, built-in wardrobes, large appliances and any fixed furniture. A mat under a cabinet is wasted heat and can overheat because the airflow is blocked.
Work on a simple plan of the room, mark the fixed items, and total the floor that will actually be covered by the finish and walked on. That usable area is the number the kit is sized against. It helps to keep the room’s shape in mind as well, because a long narrow room and a square room of the same area use the 0.5 m wide mat differently, and the turns and cut-outs affect how the rolls are laid out. The underfloor heating mat guide shows how to lay the rolls around a typical room.
How kit sizes map to area
Mats are offered in kits rated by their covered area, so the selection is a direct match against the measured usable area. The table below shows the logic rather than every stock size; the available kit list should be confirmed against the live product page and quotation.
| Usable heated area | Kit approach | Typical circuit at 160 W/m² | Notes |
|---|---|---|---|
| 1–2 m² | Single small mat | 160–320 W | Small bathroom or shower zone |
| 3–4 m² | One standard mat | 480–640 W | Typical bathroom or utility room |
| 5–6 m² | One larger mat or two rolls | 800–960 W | Kitchen or hallway |
| 8–10 m² | Multiple mats joined | 1.28–1.6 kW | Check the single-circuit load limit |
| 12 m² and above | Several mats, split circuits | 1.9 kW+ | Plan separate zones and breakers |
Where the measured area falls between two kit sizes, the rule is to size to the area that can actually be covered without overlap, using the smaller kit plus careful layout rather than a larger mat that cannot be fully laid. The cable cannot be trimmed to make an oversized kit fit, which is the subject of the next section.

What you can cut and what you cannot
This distinction causes more site damage than anything else in mat installation. The mesh fabric can be cut freely. When a run reaches a wall or has to turn a corner, the installer cuts the mesh and flips or rotates the mat, keeping the cable intact, to change direction. The cable is simply lifted from the mesh at the turn and re-routed. This lets a rectangular mat fit an L-shaped room or work around a fixture.
The heating cable can never be cut. It is a continuous resistive circuit with a fixed resistance; cutting it opens the circuit and stops that mat working, and shortening it would change the output and the current the thermostat expects. There is no way to repair a cut heating element to its original rating. The practical rule is easy to remember: cut the cloth, never the wire. If a layout seems to require cutting the cable, the kit is the wrong size or the layout is wrong, and the correct fix is a different kit or a re-plan rather than a shortened cable. The mat versus loose cable installation guide explains why a loose cable is sometimes the better tool for a heavily broken-up floor.
Choose the wattage for the finish and the room
The product page lists three area-output builds, and they are matched to the floor finish and the heat load rather than treated as upgrades.
- 150 W/m². For rooms under carpet, wood or other insulating finishes that are sensitive to high surface temperatures, and for well-insulated rooms where the floor is supplementary. The slightly lower density keeps the surface within the limits that wood and carpet manufacturers set.
- 160 W/m². The general-purpose build, the standard rating on the page, suited to tile, stone and porcelain in bathrooms, kitchens and hallways. It is the default choice for most indoor mat projects.
- 200 W/m². For wet areas, high-loss rooms and outdoor or exposed duties where a denser output is needed to offset the load. This is not used under heat-sensitive wood or carpet because the surface would run too hot.
The finish matters because it changes how the heat moves into the room. Tile and stone conduct well and suit the standard 160 build; wood and carpet add resistance and need a lower density with a floor sensor to protect the finish; a wet room or an outdoor step needs the higher density. Confirm the finish manufacturer’s maximum floor temperature and select the build against it rather than assuming more watts is always better.

A worked example from plan to kit
Take a bathroom with a gross floor area of 6 m². The fixed items are a bath tray taking 1.4 m², a toilet base at 0.4 m², and a vanity cabinet at 0.8 m². The usable heated area is 6 minus 2.6, or 3.4 m². The floor is porcelain tile, so the standard 160 W/m² build applies. The total load is 3.4 times 160, or about 544 W.
A 3.5 m² or 4 m² standard mat covers the area; the smaller 3.5 m² kit is preferred because it can be laid flat without overlap, with the mesh cut and turned at the inside corner beside the bath. The cable is routed around the toilet drain in a smooth bend. At 230 V the 544 W load draws about 2.4 A, well inside a 16 A thermostat and a 10 A circuit; at 110 V it draws close to 5 A, still comfortable. One mat, one circuit, one thermostat, GFCI protected, with the floor sensor in the gap between runs.
The same room measured only by gross area would have suggested a 6 m² kit, which is nearly double the real need and could not be laid without overlap, confirming why the usable-area step is the one that matters. The arithmetic is short, but doing it on a marked plan before ordering is the difference between a clean install and a mat that has to be returned.
Irregular rooms, fixtures and turns
Mats handle irregular shapes well as long as the cable is protected. In an L-shaped room, the mat is cut at the mesh on the inside corner and the run rotated, never folded over itself. Around a toilet drain or a pipe penetration, the mesh is cut away and the cable routed around the opening in a smooth bend that respects its minimum radius. In a long hallway, the 0.5 m rolls run back and forth along the length, with the cold tails brought back to the thermostat position.
The key discipline is to keep every cable run flat and separate, with no two cables touching or overlapping. Where the room has many fixtures, a loose cable can be easier than a mat because it can be spaced around the obstacles, and the choice should be made at the planning stage rather than forcing a mat into a floor it does not suit. The comparison in the cable versus mat guide sets out when each is the cleaner fit.
Multiple mats, circuits and the thermostat
When the total load exceeds what one thermostat or circuit can carry, the floor is split into zones. Each mat is a separate circuit with its own cold tail, and the running current is calculated from the total watts at the project voltage. The page’s mats are double-insulated, fully shielded and EMF-free, and they run on 110 V or 230 V, with the 100 V build for Japan. A 10 m² floor at 160 W/m² is 1.6 kW, which on 230 V draws about 7 A and fits a 16 A thermostat, but on 110 V draws close to 14.5 A and leaves little margin on a 16 A relay.
Where several mats exceed the relay, an external contactor controlled by the thermostat switches the load, or the floor is split into two thermostats. Each zone should also make sense as a control area, so a bathroom and a hallway on different heat loads are better as separate zones than one oversized circuit. Planning the zones and the panel capacity before the mats are ordered prevents a situation where the cable is laid but cannot be switched within the available relay ratings.

Floor preparation and the three resistance tests
A mat is thin and cannot hide an uneven subfloor, so the base has to be clean, flat and stable before the self-adhesive mesh goes down. Any sharp grit or high spot can press on the cable under the tile, and an uneven floor makes the mat sit in pockets of adhesive. A primer on a porous screed helps the adhesive mesh bond so the rolls do not lift when the tiles are set.
The cable is tested at three points to catch damage early: before laying, after the mat is fixed but before tiling, and once the floor is finished. The first reading records the cold resistance from the datasheet and confirms the mat left the factory intact; the second confirms no damage occurred during laying; the third confirms the tiling did not drive a trowel through an element. An insulation resistance test between the conductors and the earth braid also checks the double-insulated build. If a reading changes between tests, the mat is investigated before the floor is closed, not after. A failed mat found before tiling is replaceable; the same fault found under finished tile means lifting the floor. These tests are recorded against the kit and handed over, which is also the evidence the warranty position relies on.
Scene-by-scene kit selection
Small bathroom or shower. Measure the area outside the bath and toilet, select a 1–2 m² mat at 160 W/m², or 200 for a fully wet room, and run it on GFCI protection with a floor sensor. This is the simplest single-mat job.
Kitchen under tile. Subtract the cabinet and appliance footprints, total the walkable area, and select the kit or rolls that cover it at 160 W/m², routing around the fixed units without cutting the cable.
Living room under wood or carpet. Use the 150 W/m² build to stay within the finish’s temperature limit, with a floor sensor and a slightly larger heated area to offset the insulating finish.
Hallway or corridor. Run the 0.5 m rolls back and forth along the length, selecting the kit by usable area and turning the mesh at the ends. A hallway is often a good separate zone because it is heated intermittently.
Large open area. Split the floor into several mats and circuits, confirm the panel and contactor capacity, and use the 230 V supply where available to keep the current per circuit manageable.
How the budget breaks down
Buyers comparing quotations should separate the mat cost from the surrounding work, because the element itself is only part of the installed price. The mat is priced by area, with the output build and voltage affecting the unit rate, and the 200 W/m² and special-voltage builds typically sitting above the standard 160 build. On top of the mat come the thermostat and any floor sensor, the RCD and circuit work at the panel, the adhesive and tile, and the labour to lay and test.
Because the mat is only 3.6 mm thick, it avoids the cost and height of a thick screed, which is where it saves money in a retrofit compared with a traditional buried cable. A pre-spaced mat also installs faster than hand-spacing loose cable, reducing labour on a simple rectangular floor. The cases where a mat stops being the cheap option are heavily irregular rooms full of fixtures, where more of the fixed area is wasted, and very large floors that need many zones and contactors. Comparing quotations on a like-for-like installed basis, including the panel work and the testing, gives a truer number than the mat’s per-metre price alone.
Ask the supplier to itemise the kit rather than quote a single lump figure, so you can see the mat area, the number of cold tails, the thermostat and sensor, the connection and end-seal kits, and any spare mesh. A clear takeoff also shows whether the quoted mat area matches the usable area you measured, which is the easiest way to catch a kit sized to the gross room. Where several rooms are ordered together, confirm each room is a separate labelled kit with its own cold lead, rather than a bulk length that has to be split on site. The price difference between a correctly itemised order and a loose bulk quote is small, but the cost of returning an oversized mat or adding a missing connection kit after work starts is not, so the breakdown is worth requesting in writing before the deposit is paid.
Pre-order checklist
- A marked floor plan showing every fixed cabinet, bath, toilet and appliance, and the usable heated area.
- The room shape and the planned direction of the 0.5 m rolls, noting every turn and cut-out.
- The floor finish and its maximum allowed surface temperature, to choose 150, 160 or 200 W/m².
- The kit sizes that cover the usable area without overlap, and confirmation that no cable will need cutting.
- The supply voltage, including the 100 V Japanese build where relevant, and the total running current.
- Whether one thermostat switches the load directly or a contactor and split zones are required.
- The protection build: double-insulated, fully shielded, EMF-free, on an RCD-protected circuit.
Common selection mistakes
Sizing to the gross room area. Cabinets and fixtures make the real area smaller; a kit sized to the room size will be oversized and cannot be laid without overlap.
Cutting the heating cable. Only the mesh can be cut; a shortened cable is a failed mat and cannot be repaired to rating.
Using the highest wattage under wood. The 200 build overheats heat-sensitive finishes; match the density to the floor covering.
Overlapping mats to use surplus. Overlapping cable overheats the element; the correct answer is a smaller kit or a re-plan.
Ignoring the circuit limit on large floors. Multiple mats have to be split into zones and switched within the relay or contactor rating.
Data and evidence
The area-based sizing of mats follows the same heat-loss logic as loose cable, with the difference that the spacing and therefore the W/m² are fixed at manufacture rather than set on site. Radiant floor standards such as EN 1264 define floor surface limits and the use of control sensors, and floor-covering manufacturers publish their own temperature limits, which is why the 150 W/m² build is reserved for wood and carpet. Electrical insulation standards define the double-insulated, fully shielded construction and the residual-current protection required for buried elements.
Building energy research treats the heated area as the basis for the load and confirms that fixed furniture and poor airflow reduce the effective area, supporting the usable-area measurement rather than the room size. The thin 3.6 mm build is specifically documented for low-height retrofits where a thicker screed is not possible. On the factory side, SunAURA has produced heating elements since 2008, runs ISO 9001 and 14001 systems with CE and RoHS documentation, and the mat carries a 25-year warranty for correctly installed, controlled systems. No certificate number, customer name or test figure is invented, and the live product page should be treated as the source of confirmed figures.
Final recommendation
Select the mat in this order. Draw the floor, subtract every fixed item and total the usable heated area. Choose the output build from the finish, 150 for wood and carpet, 160 for tile and stone, 200 for wet and outdoor duty. Select the kit or rolls that cover the usable area without overlap, and plan the turns by cutting the mesh while never cutting the cable. On large floors, split the load into sensible zones and switch them within the relay or contactor rating at the project voltage, on an RCD-protected circuit. Done that way, the mat delivers an even, correctly limited surface with almost no added floor height, and the fixed spacing guarantees the evenness that a hand-laid cable has to work to achieve.
For the available kit sizes and the wider set of uses, work from the heating mat applications hub and the live product page, and confirm the final areas and outputs in the written quotation.